Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Nanomaterials (Basel) ; 13(16)2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37630863

RESUMO

Co-Zr amorphous alloys exhibit soft magnetic properties, whereas the Co-rich crystalline magnetic phases in this alloy system displayed a hard magnetic behavior. In this study, an initial two-phase Co-Zr composite with an overall composition of 75 at.% Co and 25 at.% Zr was processed by high-pressure torsion (HPT), and the effects of severe plastic deformation and subsequent thermal treatment on the composite's structural evolution and its magnetic properties were investigated. HPT processing allowed us to achieve an amorphous microstructure with low coercivity in its as-deformed state. To further tune the alloy's magnetic properties and study its crystallization behavior, various annealed states were investigated. The microstructural properties were correlated with the magnetic properties, and a decreasing coercivity with increasing annealing temperatures was observed despite the onset of crystallization in the amorphous alloy. At higher annealing temperatures, coercivity increased again. The results appear promising for obtaining tuneable rare-earth free magnetic materials by severe plastic deformation.

2.
Commun Chem ; 6(1): 166, 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37580376

RESUMO

Metallic nanoparticles are widely explored for boosting light-matter coupling, optoelectronic response, and improving photocatalytic performance of two-dimensional (2D) materials. However, the target area is restricted to either top or bottom of the 2D flakes. Here, we introduce an approach for edge-specific nanoparticle decoration via light-assisted reduction of silver ions and merging of silver seeds. We observe arrays of the self-limited in size silver nanoparticles along tungsten diselenide WSe2 nanoribbon edges. The density of nanoparticles is tunable by adjusting the laser fluence. Scanning electron microscopy, atomic force microscopy, and Raman spectroscopy are used to investigate the size, distribution, and photo-response of the deposited plasmonic nanoparticles on the quasi-one-dimensional nanoribbons. We report an on-surface synthesis path for creating mixed-dimensional heterostructures and heterojunctions with potential applications in opto-electronics, plasmonics, and catalysis, offering improved light matter coupling, optoelectronics response, and photocatalytic performance of 2D materials.

3.
Nanomaterials (Basel) ; 13(2)2023 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-36678097

RESUMO

Ferromagnetic (Fe or Fe20Ni80) and antiferromagnetic (NiO) phases were deformed by high-pressure torsion, a severe plastic deformation technique, to manufacture bulk-sized nanocomposites and demonstrate an exchange bias, which has been reported predominantly for bilayer thin films. High-pressure torsion deformation at elevated temperatures proved to be the key to obtaining homogeneous bulk nanocomposites. X-ray diffraction investigations detected nanocrystallinity of the ferromagnetic and antiferromagnetic phases. Furthermore, an additional phase was identified by X-ray diffraction, which formed during deformation at elevated temperatures through the reduction of NiO by Fe. Depending on the initial powder composition of Fe50NiO50 or Fe10Ni40NiO50 the new phase was magnetite or maghemite, respectively. Magnetometry measurements demonstrated an exchange bias in high-pressure torsion-processed bulk nanocomposites. Additionally, the tailoring of magnetic parameters was demonstrated by the application of different strains or post-process annealing. A correlation between the amount of applied strain and exchange bias was found. The increase of exchange bias through applied strain was related to the microstructural refinement of the nanocomposite. The nanocrystalline maghemite was considered to have a crucial impact on the observed changes of exchange bias through applied strain.

4.
Nanomaterials (Basel) ; 12(6)2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35335775

RESUMO

Exchange-coupling between soft- and hard-magnetic phases plays an important role in the engineering of novel magnetic materials. To achieve exchange coupling, a two-phase microstructure is necessary. This interface effect is further enhanced if both phase dimensions are reduced to the nanometer scale. At the same time, it is challenging to obtain large sample dimensions. In this study, powder blends and ball-milled powder blends of Fe-SmCo5 are consolidated and are deformed by high-pressure torsion (HPT), as this technique allows us to produce bulk magnetic materials of reasonable sizes. Additionally, the effect of severe deformation by ball-milling and severe plastic deformation by HPT on exchange coupling in Fe-SmCo5 composites is investigated. Due to the applied shear deformation, it is possible to obtain a texture in both phases, resulting in an anisotropic magnetic behavior and an improved magnetic performance.

5.
Radiother Oncol ; 158: 230-236, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33667585

RESUMO

BACKGROUND: Local treatment of metastases in combination with systemic therapy can prolong survival of oligo-metastasized patients. To fully exploit this potential, safe and effective treatments are needed to ensure long-term metastases control. Stereotactic body radiotherapy (SBRT) is one means, however, for moving liver tumors correct delivery of high doses is challenging. After validating equal in-vivo treatment accuracy, we analyzed a pooled multi-platform liver-SBRT-database for clinical outcome. METHODS: Local control (LC), progression-free interval (PFI), overall survival (OS), predictive factors and toxicity was evaluated in 135 patients with 227 metastases treated by gantry-based SBRT (deep-inspiratory breath-hold-gating; n = 71) and robotic-based SBRT (fiducial-tracking, n = 156) with mean gross tumor volume biological effective dose (GTV-BEDα/ß=10Gy) of 146.6 Gy10. RESULTS: One-, and five-year LC was 90% and 68.7%, respectively. On multivariate analysis, LC was significantly predicted by colorectal histology (p = 0.006). Median OS was 20 months with one- and two-year OS of 67% and 37%. On multivariate analysis, ECOG-status (p = 0.003), simultaneous chemotherapy (p = 0.003), time from metastasis detection to SBRT-treatment (≥2months; p = 0.021) and LC of the treated metastases (≥12 months, p < 0.009) were significant predictors for OS. One- and two-year PFI were 30.5% and 14%. Acute toxicity was mild and rare (14.4% grade I, 2.3% grade II, 0.6% grade III). Chronic °III/IV toxicities occurred in 1.1%. CONCLUSIONS: Patient selection, time to treatment and sufficient doses are essential to achieve optimal outcome for SBRT with active motion compensation. Local control appears favorable compared to historical control. Long-term LC of the treated lesions was associated with longer overall survival.


Assuntos
Radiocirurgia , Seguimentos , Humanos , Fígado , Radiocirurgia/efeitos adversos , Estudos Retrospectivos , Taxa de Sobrevida
6.
Nanomaterials (Basel) ; 12(1)2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-35009973

RESUMO

The paper describes the capability of magnetic softening of a coarse-grained bulk material by a severe deformation technique. Connecting the microstructure with magnetic properties, the coercive field decreases dramatically for grains smaller than the magnetic exchange length. This makes the investigation of soft magnetic properties of severely drawn pearlitic wires very interesting. With the help of the starting two-phase microstructure, it is possible to substantially refine the material, which allows the investigation of magnetic properties for nanocrystalline bulk material. Compared to the coarse-grained initial, pearlitic state, the coercivities of the highly deformed wires decrease while the saturation magnetization values increase-even beyond the value expectable from the individual constituents. The lowest coercivity in the drawn state is found to be 520 A m-1 for a wire of 24-µm thickness and an annealing treatment has a further positive effect on it. The decreasing coercivity is discussed in the framework of two opposing models: grain refinement on the one hand and dissolution of cementite on the other hand. Auxiliary measurements give a clear indication for the latter model, delivering a sufficient description of the observed evolution of magnetic properties.

7.
Strahlenther Onkol ; 197(7): 581-591, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32588102

RESUMO

PURPOSE: For step-and-shoot robotic stereotactic radiosurgery (SRS) the dose delivered over time, called local tumor-dose-rate (TDR), may strongly vary during treatment of multiple lesions. The authors sought to evaluate technical parameters influencing TDR and correlate TDR to clinical outcome. MATERIAL AND METHODS: A total of 23 patients with 162 oligo (1-3) and multiple (>3) brain metastases (OBM/MBM) treated in 33 SRS sessions were retrospectively analyzed. Median PTV were 0.11 cc (0.01-6.36 cc) and 0.50 cc (0.12-3.68 cc) for OBM and MBM, respectively. Prescription dose ranged from 16 to 20 Gy prescribed to the median 70% isodose line. The maximum dose-rate for planning target volume (PTV) percentage p in time span s during treatment (TDRs,p) was calculated for various p and s based on treatment log files and in-house software. RESULTS: TDR60min,98% was 0.30 Gy/min (0.23-0.87 Gy/min) for OBM and 0.22 Gy/min (0.12-0.63 Gy/min) for MBM, respectively, and increased by 0.03 Gy/min per prescribed Gy. TDR60min,98% strongly correlated with treatment time (ρ = -0.717, p < 0.001), monitor units (MU) (ρ = -0.767, p < 0.001), number of beams (ρ = -0.755, p < 0.001) and beam directions (ρ = -0.685, p < 0.001) as well as lesions treated per collimator (ρ = -0.708, P < 0.001). Median overall survival (OS) was 20 months and 1­ and 2­year local control (LC) was 98.8% and 90.3%, respectively. LC did not correlate with any TDR, but tumor response (partial response [PR] or complete response [CR]) correlated with all TDR in univariate analysis (e.g., TDR60min,98%: hazard ration [HR] = 0.974, confidence interval [CI] = 0.952-0.996, p = 0.019). In multivariate analysis only concomitant targeted therapy or immunotherapy and breast cancer tumor histology remained a significant factor for tumor response. Local grade ≥2 radiation-induced tissue reactions were noted in 26.3% (OBM) and 5.2% (MBM), respectively, mainly influenced by tumor volume (p < 0.001). CONCLUSIONS: Large TDR variations are noted during MBM-SRS which mainly arise from prolonged treatment times. Clinically, low TDR corresponded with decreased local tumor responses, although the main influencing factor was concomitant medication.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Neoplasias Encefálicas/cirurgia , Humanos , Doses de Radiação , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Carga Tumoral/efeitos da radiação
8.
Radiother Oncol ; 134: 158-165, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31005210

RESUMO

BACKGROUND/PURPOSE: In-vivo-accuracy analysis (IVA) of dose-delivery with active motion-management (gating/tracking) was performed based on registration of post-radiotherapeutic MRI-morphologic-alterations (MMA) to the corresponding dose-distributions of gantry-based/robotic SBRT-plans. METHODS: Forty targets in two patient cohorts were evaluated: (1) gantry-based SBRT (deep-inspiratory breath-hold-gating; GS) and (2) robotic SBRT (online fiducial-tracking; RS). The planning-CT was deformably registered to the first post-treatment contrast-enhanced T1-weighted MRI. An isodose-structure cropped to the liver (ISL) and corresponding to the contoured MMA was created. Structure and statistical analysis regarding volumes, surface-distance, conformity metrics and center-of-mass-differences (CoMD) was performed. RESULTS: Liver volume-reduction was -43.1 ±â€¯148.2 cc post-RS and -55.8 ±â€¯174.3 cc post-GS. The mean surface-distance between MMA and ISL was 2.3 ±â€¯0.8 mm (RS) and 2.8 ±â€¯1.1 mm (GS). ISL and MMA volumes diverged by 5.1 ±â€¯23.3 cc (RS) and 16.5 ±â€¯34.1 cc (GS); the median conformity index of both structures was 0.83 (RS) and 0.80 (GS). The average relative directional errors were ≤0.7 mm (RS) and ≤0.3 mm (GS); the median absolute 3D-CoMD was 3.8 mm (RS) and 4.2 mm (GS) without statistically significant differences between the two techniques. Factors influencing the IVA included GTV and PTV (p = 0.041 and p = 0.020). Four local relapses occurred without correlation to IVA. CONCLUSIONS: For the first time a method for IVA was presented, which can serve as a benchmarking-tool for other treatment techniques. Both techniques have shown median deviations <5 mm of planned dose and MMA. However, IVA also revealed treatments with errors ≥5 mm, suggesting a necessity for patient-specific safety-margins. Nevertheless, the treatment accuracy of well-performed active motion-compensated liver SBRT seems not to be a driving factor for local treatment failure.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Suspensão da Respiração , Estudos de Coortes , Feminino , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos , Robótica/métodos
9.
Melanoma Res ; 29(2): 187-195, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30802230

RESUMO

The aim was to evaluate toxicity and oncological outcome of combined stereotactic radiosurgery (SRS) and immunotherapy or targeted therapy in patients with multiple brain metastases originating from malignant melanoma. Despite the fact that both SRS and kinase inhibitors or immune checkpoint inhibitors are considered standard treatment options for this indication, the optimal combination and sequence of these modalities remains largely unknown, especially for patients with a high number of brain metastases. For this retrospective analysis, conducted in two large SRS dedicated centers, we identified patients with brain metastases from malignant melanoma and simultaneous application of immunotherapy or targeted therapy within 30 days of SRS. Forty-eight patients with a total of 250 lesions (median: 3) were treated in 65 single fraction SRS sessions from 2012 to 2018. After a median follow-up of 8.3 months (range: 1.2-43.6 months), the 6-month and 1-year overall survival rates were 75.3 and 50.8%, respectively. The local control rate at one year was 89.5%. Immunotherapy and the application of systemic treatment directly before or concomitant to SRS were both associated with improved overall survival (P=0.037 and 0.045, respectively). We observed four grade III toxicities, of which only two can be clearly attributed to the combined treatment. Various combinations of SRS and kinase inhibitors or immune checkpoint inhibitors appear feasible and provide promising oncological results and safety profiles for treating few (n=1-4) and also multiple (n≥5) melanoma brain metastases.


Assuntos
Neoplasias Encefálicas/secundário , Imunoterapia/métodos , Melanoma/radioterapia , Melanoma/cirurgia , Inibidores de Proteínas Quinases/uso terapêutico , Radiocirurgia/métodos , Neoplasias Cutâneas/radioterapia , Neoplasias Cutâneas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/patologia , Feminino , Humanos , Masculino , Melanoma/patologia , Pessoa de Meia-Idade , Inibidores de Proteínas Quinases/farmacologia , Estudos Retrospectivos , Neoplasias Cutâneas/patologia
10.
Nanomaterials (Basel) ; 9(1)2018 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-30577581

RESUMO

Samples consisting of one ferromagnetic and one diamagnetic component which are immiscible at the thermodynamic equilibrium (Co-Cu, Fe-Cu, Fe-Ag) are processed by high-pressure torsion at various compositions. The received microstructures are investigated by electron microscopy and synchrotron X-ray diffraction, showing a microstructural saturation. Results gained from microstructural investigations are correlated to magnetometry data. The Co-Cu samples show mainly ferromagnetic behavior and a decrease in coercivity with increasing Co-content. The saturation microstructure of Fe-Cu samples is found to be dual phase. Results of magnetic measurements also revealed the occurrence of two different magnetic phases in this system. For Fe-Ag, the microstructural and magnetic results indicate that no intermixing between the elemental phases takes place.

11.
Front Oncol ; 8: 171, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29868486

RESUMO

INTRODUCTION: We retrospectively evaluated the efficacy and toxicity of gross tumor volume (GTV) mean dose optimized stereotactic body radiation therapy (SBRT) for primary and secondary lung tumors with and without robotic real-time motion compensation. MATERIALS AND METHODS: Between 2011 and 2017, 208 patients were treated with SBRT for 111 primary lung tumors and 163 lung metastases with a median GTV of 8.2 cc (0.3-174.0 cc). Monte Carlo dose optimization was performed prioritizing GTV mean dose at the potential cost of planning target volume (PTV) coverage reduction while adhering to safe normal tissue constraints. The median GTV mean biological effective dose (BED)10 was 162.0 Gy10 (34.2-253.6 Gy10) and the prescribed PTV BED10 ranged 23.6-151.2 Gy10 (median, 100.8 Gy10). Motion compensation was realized through direct tracking (44.9%), fiducial tracking (4.4%), and internal target volume (ITV) concepts with small (≤5 mm, 33.2%) or large (>5 mm, 17.5%) motion. The local control (LC), progression-free survival (PFS), overall survival (OS), and toxicity were analyzed. RESULTS: Median follow-up was 14.5 months (1-72 months). The 2-year actuarial LC, PFS, and OS rates were 93.1, 43.2, and 62.4%, and the median PFS and OS were 18.0 and 39.8 months, respectively. In univariate analysis, prior local irradiation (hazard ratio (HR) 0.18, confidence interval (CI) 0.05-0.63, p = 0.01), GTV/PTV (HR 1.01-1.02, CI 1.01-1.04, p < 0.02), and PTV prescription, mean GTV, and maximum plan BED10 (HR 0.97-0.99, CI 0.96-0.99, p < 0.01) were predictive for LC while the tracking method was not (p = 0.97). For PFS and OS, multivariate analysis showed Karnofsky Index (p < 0.01) and tumor stage (p ≤ 0.02) to be significant factors for outcome prediction. Late radiation pneumonitis or chronic rip fractures grade 1-2 were observed in 5.3% of the patients. Grade ≥3 side effects did not occur. CONCLUSION: Robotic SBRT is a safe and effective treatment for lung tumors. Reducing the PTV prescription and keeping high GTV mean doses allowed the reduction of toxicity while maintaining high local tumor control. The use of real-time motion compensation is strongly advised, however, well-performed ITV motion compensation may be used alternatively when direct tracking is not feasible.

12.
Strahlenther Onkol ; 194(9): 843-854, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29802435

RESUMO

PURPOSE: To investigate the quality of treatment plans of spinal radiosurgery derived from different planning and delivery systems. The comparisons include robotic delivery and intensity modulated arc therapy (IMAT) approaches. Multiple centers with equal systems were used to reduce a bias based on individual's planning abilities. The study used a series of three complex spine lesions to maximize the difference in plan quality among the various approaches. METHODS: Internationally recognized experts in the field of treatment planning and spinal radiosurgery from 12 centers with various treatment planning systems participated. For a complex spinal lesion, the results were compared against a previously published benchmark plan derived for CyberKnife radiosurgery (CKRS) using circular cones only. For two additional cases, one with multiple small lesions infiltrating three vertebrae and a single vertebra lesion treated with integrated boost, the results were compared against a benchmark plan generated using a best practice guideline for CKRS. All plans were rated based on a previously established ranking system. RESULTS: All 12 centers could reach equality (n = 4) or outperform (n = 8) the benchmark plan. For the multiple lesions and the single vertebra lesion plan only 5 and 3 of the 12 centers, respectively, reached equality or outperformed the best practice benchmark plan. However, the absolute differences in target and critical structure dosimetry were small and strongly planner-dependent rather than system-dependent. Overall, gantry-based IMAT with simple planning techniques (two coplanar arcs) produced faster treatments and significantly outperformed static gantry intensity modulated radiation therapy (IMRT) and multileaf collimator (MLC) or non-MLC CKRS treatment plan quality regardless of the system (mean rank out of 4 was 1.2 vs. 3.1, p = 0.002). CONCLUSIONS: High plan quality for complex spinal radiosurgery was achieved among all systems and all participating centers in this planning challenge. This study concludes that simple IMAT techniques can generate significantly better plan quality compared to previous established CKRS benchmarks.


Assuntos
Benchmarking , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral , Vértebras Torácicas , Idoso , Algoritmos , Fracionamento da Dose de Radiação , Humanos , Recidiva Local de Neoplasia/radioterapia , Órgãos em Risco , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/instrumentação , Reirradiação , Procedimentos Cirúrgicos Robóticos/instrumentação , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Vértebras Torácicas/cirurgia
13.
Strahlenther Onkol ; 194(5): 414-424, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29404626

RESUMO

PURPOSE: For assessing healthy liver reactions after robotic SBRT (stereotactic body radiotherapy), we investigated early morphologic alterations on MRI (magnetic resonance imaging) with respect to patient and treatment plan parameters. PATIENTS AND METHODS: MRI data at 6-17 weeks post-treatment from 22 patients with 42 liver metastases were analyzed retrospectively. Median prescription dose was 40 Gy delivered in 3-5 fractions. T2- and T1-weighted MRI were registered to the treatment plan. Absolute doses were converted to EQD2 (Equivalent dose in 2Gy fractions) with α/ß-ratios of 2 and 3 Gy for healthy, and 8 Gy for modelling pre-damaged liver tissue. RESULTS: Sharply defined, centroid-shaped morphologic alterations were observed outside the high-dose volume surrounding the GTV. On T2-w MRI, hyperintensity at EQD2 isodoses of 113.3 ± 66.1 Gy2, 97.5 ± 54.7 Gy3, and 66.5 ± 32.0 Gy8 significantly depended on PTV dimension (p = 0.02) and healthy liver EQD2 (p = 0.05). On T1-w non-contrast MRI, hypointensity at EQD2 isodoses of 113.3 ± 49.3 Gy2, 97.4 ± 41.0 Gy3, and 65.7 ± 24.2 Gy8 significantly depended on prior chemotherapy (p = 0.01) and total liver volume (p = 0.05). On T1-w gadolinium-contrast delayed MRI, hypointensity at EQD2 isodoses of 90.6 ± 42.5 Gy2, 79.3 ± 35.3 Gy3, and 56.6 ± 20.9 Gy8 significantly depended on total (p = 0.04) and healthy (p = 0.01) liver EQD2. CONCLUSIONS: Early post-treatment changes in healthy liver tissue after robotic SBRT could spatially be correlated to respective isodoses. Median nominal doses of 10.1-11.3 Gy per fraction (EQD2 79-97 Gy3) induce characteristic morphologic alterations surrounding the lesions, potentially allowing for dosimetric in-vivo accuracy assessments. Comparison to other techniques and investigations of the short- and long-term clinical impact require further research.


Assuntos
Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Fígado , Imageamento por Ressonância Magnética , Lesões por Radiação/diagnóstico por imagem , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Adulto , Idoso , Idoso de 80 Anos ou mais , Fracionamento da Dose de Radiação , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/efeitos da radiação , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/instrumentação , Estatística como Assunto
14.
Strahlenther Onkol ; 194(2): 143-155, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28875297

RESUMO

PURPOSE: We retrospectively evaluated the patterns of failure for robotic guided real-time breathing-motion-compensated (BMC) stereotactic body radiation therapy (SBRT) in the treatment of tumors in moving organs. PATIENTS AND METHODS: Between 2011 and 2016, a total of 198 patients with 280 lung, liver, and abdominal tumors were treated with BMC-SBRT. The median gross tumor volume (GTV) was 12.3 cc (0.1-372.0 cc). Medians of mean GTV BEDα/ß =10 Gy (BED = biological effective dose) was 148.5 Gy10 (31.5-233.3 Gy10) and prescribed planning target volume (PTV) BEDα/ß =10 Gy was 89.7 Gy10 (28.8-151.2 Gy10), respectively. We analyzed overall survival (OS) and local control (LC) based on various factors, including BEDs with α/ß ratios of 15 Gy (lung metastases), 21 Gy (primary lung tumors), and 27 Gy (liver metastases). RESULTS: Median follow-up was 10.4 months (2.0-59.0 months). The 2­year actuarial LC was 100 and 86.4% for primary early and advanced stage lung tumors, respectively, 100% for lung metastases, 82.2% for liver metastases, and 90% for extrapulmonary extrahepatic metastases. The 2­year OS rate was 47.9% for all patients. In uni- and multivariate analysis, comparatively lower PTV prescription dose (equivalence of 3 × 12-13 Gy) and higher average GTV dose (equivalence of 3 × 18 Gy) to current practice were significantly associated with LC. For OS, Karnofsky performance score (100%), gender (female), and SBRT without simultaneous chemotherapy were significant prognostic factors. Grade 3 side effects were rare (0.5%). CONCLUSIONS: Robotic guided BMC-SBRT can be considered a safe and effective treatment for solid tumors in moving organs. To reach sufficient local control rates, high average GTV doses are necessary. Further prospective studies are warranted to evaluate these points.


Assuntos
Neoplasias Abdominais/cirurgia , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos , Radioterapia Guiada por Imagem/métodos , Respiração , Procedimentos Cirúrgicos Robóticos/instrumentação , Neoplasias Abdominais/mortalidade , Neoplasias Abdominais/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/secundário , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Radiocirurgia/instrumentação , Estudos Retrospectivos , Falha de Tratamento , Carga Tumoral/fisiologia
15.
Materials (Basel) ; 10(11)2017 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-29120407

RESUMO

Rapid progress in the reduction of substrate thickness for silicon-based microelectronics leads to a significant reduction of the device bending stiffness and the need to address its implication for the thermo-mechanical fatigue behavior of metallization layers. Results on 5 µm thick Cu films reveal a strong substrate thickness-dependent microstructural evolution. Substrates with hs = 323 and 220 µm showed that the Cu microstructure exhibits accelerated grain growth and surface roughening. Moreover, curvature-strain data indicates that Stoney's simplified curvature-stress relation is not valid for thin substrates with regard to the expected strains, but can be addressed using more sophisticated plate bending theories.

16.
Int J Radiat Oncol Biol Phys ; 97(4): 839-848, 2017 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-28244421

RESUMO

PURPOSE: Although the metric precision of robotic stereotactic body radiation therapy in the presence of breathing motion is widely known, we investigated the dosimetric implications of breathing phase-related residual tracking errors. METHODS AND MATERIALS: In 24 patients (28 liver metastases) treated with the CyberKnife, we recorded the residual correlation, prediction, and rotational tracking errors from 90 fractions and binned them into 10 breathing phases. The average breathing phase errors were used to shift and rotate the clinical tumor volume (CTV) and planning target volume (PTV) for each phase to calculate a pseudo 4-dimensional error dose distribution for comparison with the original planned dose distribution. RESULTS: The median systematic directional correlation, prediction, and absolute aggregate rotation errors were 0.3 mm (range, 0.1-1.3 mm), 0.01 mm (range, 0.00-0.05 mm), and 1.5° (range, 0.4°-2.7°), respectively. Dosimetrically, 44%, 81%, and 92% of all voxels differed by less than 1%, 3%, and 5% of the planned local dose, respectively. The median coverage reduction for the PTV was 1.1% (range in coverage difference, -7.8% to +0.8%), significantly depending on correlation (P=.026) and rotational (P=.005) error. With a 3-mm PTV margin, the median coverage change for the CTV was 0.0% (range, -1.0% to +5.4%), not significantly depending on any investigated parameter. In 42% of patients, the 3-mm margin did not fully compensate for the residual tracking errors, resulting in a CTV coverage reduction of 0.1% to 1.0%. CONCLUSIONS: For liver tumors treated with robotic stereotactic body radiation therapy, a safety margin of 3 mm is not always sufficient to cover all residual tracking errors. Dosimetrically, this translates into only small CTV coverage reductions.


Assuntos
Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Robótica/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Movimento (Física) , Radiocirurgia , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade , Resultado do Tratamento , Carga Tumoral/efeitos da radiação
17.
J Appl Clin Med Phys ; 17(3): 313-330, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167291

RESUMO

Stereotactic radiosurgery (SRS) is the accurate, conformal delivery of high-dose radiation to well-defined targets while minimizing normal structure doses via steep dose gradients. While inverse treatment planning (ITP) with computerized optimization algorithms are routine, many aspects of the planning process remain user-dependent. We performed an international, multi-institutional benchmark trial to study planning variability and to analyze preferable ITP practice for spinal robotic radiosurgery. 10 SRS treatment plans were generated for a complex-shaped spinal metastasis with 21 Gy in 3 fractions and tight constraints for spinal cord (V14Gy < 2 cc, V18Gy < 0.1 cc) and target (coverage > 95%). The resulting plans were rated on a scale from 1 to 4 (excellent-poor) in five categories (constraint compliance, optimization goals, low-dose regions, ITP complexity, and clinical acceptability) by a blinded review panel. Additionally, the plans were mathemati-cally rated based on plan indices (critical structure and target doses, conformity, monitor units, normal tissue complication probability, and treatment time) and compared to the human rankings. The treatment plans and the reviewers' rankings varied substantially among the participating centers. The average mean overall rank was 2.4 (1.2-4.0) and 8/10 plans were rated excellent in at least one category by at least one reviewer. The mathematical rankings agreed with the mean overall human rankings in 9/10 cases pointing toward the possibility for sole mathematical plan quality comparison. The final rankings revealed that a plan with a well-balanced trade-off among all planning objectives was preferred for treatment by most par-ticipants, reviewers, and the mathematical ranking system. Furthermore, this plan was generated with simple planning techniques. Our multi-institutional planning study found wide variability in ITP approaches for spinal robotic radiosurgery. The participants', reviewers', and mathematical match on preferable treatment plans and ITP techniques indicate that agreement on treatment planning and plan quality can be reached for spinal robotic radiosurgery.


Assuntos
Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Robótica/métodos , Neoplasias da Coluna Vertebral/cirurgia , Algoritmos , Benchmarking , Humanos , Agências Internacionais , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
18.
Radiat Oncol ; 11: 74, 2016 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-27236333

RESUMO

BACKGROUND: We retrospectively evaluated the efficacy and toxicity of gross tumor volume (GTV) mean-dose-optimized and real-time motion-compensated robotic stereotactic body radiation therapy (SBRT) in the treatment of liver metastases. METHODS: Between March 2011 and July 2015, 52 patients were treated with SBRT for a total of 91 liver metastases (one to four metastases per patient) with a median GTV volume of 12 cc (min 1 cc, max 372 cc). The optimization of mean GTV dose was prioritized during treatment planning at the potential cost of planning target volume (PTV) coverage reduction while adhering to safe normal tissue constraints. The delivered median GTV biological effective dose (BED10) was 142.1 Gy10 (range, 60.2 Gy10 -165.3 Gy10) and the prescribed PTV BED10 ranged from 40.6 Gy10 to 112.5 Gy10 (median, 86.1 Gy10). We analyzed local control (LC), progression-free interval (PFI), overall survival (OS), and toxicity. RESULTS: Median follow-up was 17 months (range, 2-49 months). The 2-year actuarial LC, PFI, and OS rates were 82.1, 17.7, and 45.0 %, and the median PFI and OS were 9 and 23 months, respectively. In univariate analysis histology (p < 0.001), PTV prescription BED10 (HR 0.95, CI 0.91-0.98, p = 0.002) and GTV mean BED10 (HR 0.975, CI 0.954-0.996, p = 0.011) were predictive for LC. Multivariate analysis showed that only extrahepatic disease status at time of treatment was a significant factor (p = 0.033 and p = 0.009, respectively) for PFI and OS. Acute nausea or fatigue grade 1 was observed in 24.1 % of the patients and only 1 patient (1.9 %) had a side effect of grade ≥ 2. CONCLUSIONS: Robotic real-time motion-compensated SBRT is a safe and effective treatment for one to four liver metastases. Reducing the PTV prescription dose and keeping a high mean GTV dose allowed the reduction of toxicity while maintaining a high local control probability for the treated lesions.


Assuntos
Neoplasias Hepáticas/cirurgia , Radiocirurgia , Dosagem Radioterapêutica/normas , Robótica , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Fracionamento da Dose de Radiação , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...